0x00 Îó²î¸ÅÊö

2022Äê6ÔÂ16ÈÕ£¬ £¬£¬£¬£¬£¬Ñо¿Ö°Ô±¹ûÕæÅû¶ÁËÎ÷ÃÅ×ÓSINECÍøÂçÖÎÀíϵͳ (NMS)ÖеÄ15¸öÇå¾²Îó²îµÄÏêϸÐÅÏ¢£¬ £¬£¬£¬£¬£¬ÀÖ³ÉʹÓÃÕâЩÎó²î¿ÉÄܵ¼Ö¾ܾøÐ§ÀÍ¡¢Æ¾Ö¤Ð¹Â¶ºÍÔ¶³Ì´úÂëÖ´Ðеȡ£ ¡£¡£

 

0x01 Îó²îÏêÇé

Õâ15¸öÎó²î¾ùλÓÚSIEMENS SINEC NMSÖУ¬ £¬£¬£¬£¬£¬SINEC ͨ³£ÔÚÍøÂçÍØÆËÖд¦ÓÚÖÐÐÄλÖ㬠£¬£¬£¬£¬£¬ÕâЩÎó²î¿ÉÄܱ»ÓÃÀ´ÊµÏÖÕì̽¡¢ºáÏòÒÆ¶¯ºÍÌØÈ¨Éý¼¶¡£ ¡£¡£Îó²îÏêÇéÈçÏ£º

CVE-ID

Ãû³Æ

˵Ã÷

CVSSÆÀ·Ö

CVE-2021-33722

SIEMENS SINEC NMS·¾¶±éÀúÎó²î

ÓÉÓÚ¶ÔĿ¼µÄ·¾¶ÃûÏÞÖÆ²»µ±£¬ £¬£¬£¬£¬£¬SIEMENS SINEC NMSÔÚµ¼³ö¹Ì¼þÈÝÆ÷ʱ±£´æÂ·¾¶±éÀúÎó²î£¬ £¬£¬£¬£¬£¬¿ÉÔÚ¾­ÓÉÉí·ÝÑéÖ¤µÄÇéÐÎÏÂʹÓôËÎó²îÔÚÊÜÓ°ÏìµÄϵͳÉϽ¨Éèí§ÒâÎļþ»òÖ´ÐдúÂë¡£ ¡£¡£

7.2

CVE-2021-33723

SIEMENS SINEC NMSÕË»§½ÓÊÜÎó²î

ÓÉÓÚÊÚȨ²»µ±£¬ £¬£¬£¬£¬£¬SIEMENS SINEC NMS±£´æÕË»§½ÓÊÜÎó²î£¬ £¬£¬£¬£¬£¬Èκξ­ÓÉÉí·ÝÑéÖ¤µÄÓû§¿ÉʹÓôËÎó²î»á¼ûÖÎÀíÔ±ÕÊ»§£¬ £¬£¬£¬£¬£¬ÒÔ¼°Ö»ÓÐSINECϵͳÖÎÀíÔ±²Å»ª»á¼ûµÄ¹¦Ð§¡£ ¡£¡£

8.8

CVE-2021-33724

SIEMENS SINEC NMS·¾¶±éÀúÎó²î

ÓÉÓÚ¶ÔĿ¼µÄ·¾¶ÃûÏÞÖÆ²»µ±£¬ £¬£¬£¬£¬£¬SIEMENS SINEC NMS±£´æí§ÒâÎļþɾ³ýÎó²î£¬ £¬£¬£¬£¬£¬¿ÉʹÓôËÎó²îɾ³ýÓû§¿ØÖÆÂ·¾¶ÏµÄí§ÒâÎļþ»òĿ¼¡£ ¡£¡£

6.5

CVE-2021-33725

SIEMENS SINEC NMS·¾¶±éÀúÎó²î

ÓÉÓÚ¶ÔĿ¼µÄ·¾¶ÃûÏÞÖÆ²»µ±£¬ £¬£¬£¬£¬£¬SIEMENS SINEC NMS±£´æí§ÒâÎļþɾ³ýÎó²î£¬ £¬£¬£¬£¬£¬¿ÉʹÓôËÎó²îɾ³ýÓû§¿ØÖÆÂ·¾¶ÏµÄí§ÒâÎļþ»òĿ¼¡£ ¡£¡£

4.9

CVE-2021-33726

SIEMENS SINEC NMS·¾¶±éÀúÎó²î

ÓÉÓÚ¶ÔĿ¼µÄ·¾¶ÃûÏÞÖÆ²»µ±£¬ £¬£¬£¬£¬£¬SIEMENS SINEC NMS±£´æÂ·¾¶±éÀúÎó²î£¬ £¬£¬£¬£¬£¬ÇÒÎÞ·¨×¼È·¼ì²éÏà¶Ô·¾¶ÊÇ·ñÈÔÔÚÔ¤ÆÚµÄÄ¿µÄĿ¼ÖУ¬ £¬£¬£¬£¬£¬¿ÉʹÓôËÎó²îɾ³ýÓû§¿ØÖÆÂ·¾¶ÏµÄí§ÒâÎļþ»òĿ¼¡£ ¡£¡£

6.5

CVE-2021-33727

SIEMENS SINEC NMSÐÅϢй¶Îó²î

¿ÉÔÚ¾­ÓÉÉí·ÝÑéÖ¤µÄÇéÐÎÏÂʹÓôËÎó²îÏÂÔØÈκÎÓû§µÄÓû§ÉèÖÃÎļþ£¬ £¬£¬£¬£¬£¬µ¼ÖÂÃô¸ÐÐÅϢй¶¡£ ¡£¡£

6.5

CVE-2021-33728

SIEMENS SINEC NMS·´ÐòÁл¯Îó²î

SIEMENS SINEC NMSÔÊÐíÉÏ´«JSON¹¤¾ß£¬ £¬£¬£¬£¬£¬ÕâЩ¹¤¾ß±»·´ÐòÁл¯ÎªJava¹¤¾ß¡£ ¡£¡£ÓÉÓÚ¶ÔÓû§ÌṩµÄÄÚÈݾÙÐв»Çå¾²µÄ·´ÐòÁл¯£¬ £¬£¬£¬£¬£¬ÌØÈ¨Óû§¿ÉʹÓôËÎó²îµ¼Ö´úÂëÖ´ÐС£ ¡£¡£

7.2

CVE-2021-33729

SIEMENS SINEC NMS SQL ×¢ÈëÎó²î

SIEMENS SINEC NMS ±£´æSQL ×¢ÈëÎó²î£¬ £¬£¬£¬£¬£¬¾­ÓÉÉí·ÝÑéÖ¤µÄÓû§¿Éͨ¹ý½«¹Ì¼þÈÝÆ÷µ¼ÈëÊÜÓ°ÏìµÄϵͳ²¢ÔÚÍâµØÊý¾Ý¿âÖÐÖ´ÐÐí§ÒâÏÂÁî¡£ ¡£¡£

8.8

CVE-2021-33730¡¢CVE-2021-33731¡¢CVE-2021-33732¡¢CVE-2021-33733¡¢CVE-2021-33734¡¢CVE-2021-33735¡¢CVE-2021-33736

SIEMENS SINEC NMS SQL ×¢ÈëÎó²î

SIEMENS SINEC NMS ±£´æ¶à¸öSQL ×¢ÈëÎó²î£¬ £¬£¬£¬£¬£¬¾­ÓÉÉí·ÝÑéÖ¤µÄÓû§¿Éͨ¹ý·¢ËÍÈ«ÐÄÖÆ×÷µÄÇëÇó£¬ £¬£¬£¬£¬£¬ÊµÏÖÔÚÍâµØÊý¾Ý¿âÖÐÖ´ÐÐí§ÒâÏÂÁî¡£ ¡£¡£

7.2

 

Ó°Ïì¹æÄ£

SIEMENS SINEC NMS °æ±¾< V1.0 SP2 Update 1

 

0x02 ´¦Öóͷ£½¨Òé

ÏÖÔÚÕâЩÎó²îÒѾ­ÐÞ¸´£¬ £¬£¬£¬£¬£¬ÊÜÓ°ÏìµÄÎ÷ÃÅ×ÓÓû§¿ÉÒÔ¸üе½SIEMENS SINEC NMS V1.0 SP2 Update 1£¨ÒÑÓÚ2021Äê10ÔÂ12ÈÕÐû²¼£©»ò¸ü¸ß°æ±¾¡£ ¡£¡£

ÏÂÔØÁ´½Ó£º

https://support.industry.siemens.com/cs/document/109802731/release-of-update-1-for-sinec-nms-v1-0-sp2?dti=0&lc=en-WW

 

0x03 ²Î¿¼Á´½Ó

https://cert-portal.siemens.com/productcert/html/ssa-163251.html

https://claroty.com/2022/06/16/blog-research-securing-network-management-systems-part-3-siemens-sinec-nms/

https://thehackernews.com/2022/06/over-dozen-flaws-found-in-siemens.html

 

0x04 ¸üа汾

°æ±¾

ÈÕÆÚ

ÐÞ¸ÄÄÚÈÝ

V1.0

2022-06-20

Ê×´ÎÐû²¼

 

0x05 ¸½Â¼

¼øºÚµ£±£Íø¼ò½é

¼øºÚµ£±£Íø½¨ÉèÓÚ1996Ä꣬ £¬£¬£¬£¬£¬ÊÇÓÉÁôÃÀ²©Ê¿ÑÏÍû¼ÑŮʿ½¨ÉèµÄ¡¢ÓµÓÐÍêÈ«×ÔÖ÷֪ʶ²úȨµÄÐÅÏ¢Çå¾²¸ß¿Æ¼¼ÆóÒµ¡£ ¡£¡£ÊǺ£ÄÚ×î¾ßʵÁ¦µÄÐÅÏ¢Çå¾²²úÆ·¡¢Ç徲ЧÀͽâ¾ö¼Æ»®µÄÁ캽ÆóÒµÖ®Ò»¡£ ¡£¡£

¹«Ë¾×ܲ¿Î»ÓÚ±±¾©ÊÐÖйشåÈí¼þÔ°¼øºÚµ£±£Íø´óÏ㬠£¬£¬£¬£¬£¬¹«Ë¾Ô±¹¤½ü4000ÈË£¬ £¬£¬£¬£¬£¬Ñз¢ÍŶÓ1200ÓàÈË, ÊÖÒÕЧÀÍÍŶÓ1300ÓàÈË¡£ ¡£¡£ÔÚÌìϸ÷Ê¡¡¢ÊС¢×ÔÖÎÇøÉèÁ¢·ÖÖ§»ú¹¹ÁùÊ®¶à¸ö£¬ £¬£¬£¬£¬£¬ÓµÓÐÁýÕÖÌìϵÄÏúÊÛϵͳ¡¢ÇþµÀϵͳºÍÊÖÒÕÖ§³Öϵͳ¡£ ¡£¡£¹«Ë¾ÓÚ2010Äê6ÔÂ23ÈÕÔÚÉîÛÚÖÐС°å¹ÒÅÆÉÏÊС£ ¡£¡££¨¹ÉƱ´úÂ룺002439£©

¶àÄêÀ´£¬ £¬£¬£¬£¬£¬¼øºÚµ£±£ÍøÖÂÁ¦ÓÚÌṩ¾ßÓйú¼Ê¾ºÕùÁ¦µÄ×ÔÖ÷Á¢ÒìµÄÇå¾²²úÆ·ºÍ×î¼Ñʵ¼ùЧÀÍ£¬ £¬£¬£¬£¬£¬×ÊÖú¿Í»§ÖÜÈ«ÌáÉýÆäIT»ù´¡ÉèÊ©µÄÇå¾²ÐÔºÍÉú²úЧÄÜ£¬ £¬£¬£¬£¬£¬Îª´òÔìºÍÌáÉý¹ú¼Ê»¯µÄÃñ×åÐÅÏ¢Çå¾²¹¤ÒµÁì¾üÆ·ÅÆ¶ø²»Ð¸Æð¾¢¡£ ¡£¡£

 

¹ØÓÚ¼øºÚµ£±£Íø

¼øºÚµ£±£ÍøÇå¾²Ó¦¼±ÏìÓ¦ÖÐÐÄÖ÷ÒªÕë¶ÔÖ÷ÒªÇå¾²Îó²îµÄÔ¤¾¯¡¢¸ú×ٺͷÖÏíÈ«Çò×îеÄÍþвÇ鱨ºÍÇå¾²±¨¸æ¡£ ¡£¡£

¹Ø×¢ÒÔϹ«Öںţ¬ £¬£¬£¬£¬£¬»ñȡȫÇò×îÐÂÇå¾²×ÊѶ£º

 

image.png